Products

JUT10-95/2 Industrial disteibutionem terminalem caudices stamina type

Brevis descriptio:

breviter.Modulare consilium, lapsus inter se, compages compacta Utere flamma retardat machinalis materias, adaequatae vires et duritiem ne brevi ambitu et flamma retardant consilium.

 

 


Data technica

negotium notitia

download

Certification

Product Tags

Commodum

* Salvum 50%-70% sumptus ad busbar et rami funiculos comparet
* Flexibile nexum solutionem cum junctionibus praebet
* Consilium patented certum et late spatium praebet contactum
Minimum resistentia contactus puncta
* Forma anti-canus, non flammabilis, calor & materia resistentiae impulsus, transierunt 160A/mm2 breves circuitus accentus test et UL 94 V-0 flammabilitas test

Singula parametri

Product description
Product Image        
Product numerus JUT10-95 JUT10-95/2 JUT10-150 JUT10-240
genus productum Rail wiring distribution obstructionum Rail wiring distribution obstructionum Rail wiring distribution obstructionum Rail wiring distribution obstructionum
Mechanica structura Genus nexu sequela Genus nexu sequela Genus nexu sequela Genus nexu sequela
stratis 1 1 1 1
Electric potential 2 4 2 2
nexum volumen 2 4 2 2
Rated sectione transversali 50-95mm2 50-95mm2 50-150mm2 95-240mm2
Ratum current 245A 245A 320A 425
Rated voltage 1000V 1000V 1000V 1000V
apertum latus panel Ita Ita Ita Ita
grounding pedes no no no no
alius Connexio plenas clausuras debet instituere ut clausurae NS 35/7,5 vel NS 35/15 . instituantur Connexio plenas clausuras debet instituere ut clausurae NS 35/7,5 vel NS 35/15 . instituantur Connexio plenas clausuras debet instituere ut clausurae NS 35/7,5 vel NS 35/15 . instituantur Connexio plenas clausuras debet instituere ut clausurae NS 35/7,5 vel NS 35/15 . instituantur
Applicationem agri Late in nexu electrica, industriae Late in nexu electrica, industriae Late in nexu electrica, industriae Late in nexu electrica, industriae
color (griseo) (griseo) (viridis) (flavis) (hyacintho) customizable (griseo) (griseo) (viridis) (flavis) (hyacintho) customizable (griseo) (griseo) (viridis) (flavis) (hyacintho) customizable (griseo) (griseo) (viridis) (flavis) (hyacintho) customizable
Wiring notitia
linea contactus
Tandem nudare 8mm — 10mm 8mm — 10mm 8mm — 10mm 8mm — 10mm
Rigid Conductor Cross Section 50mm² — 95mm² 50mm² — 95mm² 50mm² — 150mm² 95mm² — 240mm²
Flexibile sectione transversali conductor 50mm² — 95mm² 50mm² — 95mm² 50mm² — 150mm² 95mm² — 240mm²
Rigid Conductor Cross Section AWG 1/0~6 1/0~6 1/0~6 1/0~6
Flexible Conductor Cross Section AWG 1/0~6 1/0~6 1/0~6 1/0~6
magnitudine
crassitudine 42mm 42mm 28.6mm 37mm
latitudo 89mm 89mm 98mm 130mm
summus 51.5mm 51.5mm 60.5mm 66mm
NS35/7.5 altum 59mm 59mm 68mm 73.5mm
NS35/15 altum - - -  
NS15/5.5 altum        
Materia proprietatibus
Flamma retardat gradus, in linea cum UL94 V0 V0 V0 V0
Nulla materia PA PA PA PA
Nulla materia coetus I I I I
IEC parametri Electrical
vexillum test EN61238-1, EN60947-7-2 EN61238-1, EN60947-7-2 EN61238-1, EN60947-7-2 EN61238-1, EN60947-7-2
Rated voltage(III/3) 1000V 1000V 1000V 1000V
Ratum current(III/3) 245A 245A 320A 425A
Rated fluctu voltage 8kv 8kv 8kv 8kv
Overvoltage classis III III III III
pollutio level 3 3 3 3
Electrical perficientur test
Surge Voltage Test Results Transierunt test Transierunt test Transierunt test Transierunt test
Potestas frequentiae sustinere voltage test eventus Transierunt test Transierunt test Transierunt test Transierunt test
Temperatus oritur test eventus Transierunt test Transierunt test Transierunt test Transierunt test
condiciones environmental
Ambiens temperatus (operans) -60 °C - 105 °C (Maximum breve tempus temperaturae operating, notae electricae sunt respectivae ad temperiem). -60 °C - 105 °C (Maximum breve tempus temperaturae operating, notae electricae sunt respectivae ad temperiem). -60 °C - 105 °C (Maximum breve tempus temperaturae operating, notae electricae sunt respectivae ad temperiem). -60 °C - 105 °C (Maximum breve tempus temperaturae operating, notae electricae sunt respectivae ad temperiem).
Ambiens temperatus (repono / onerariam) -25 °C — 60 °C (brevis terminus (usque ad 24 horas), -60 °C ad 70°C) -25 °C — 60 °C (brevis terminus (usque ad 24 horas), -60 °C ad 70°C) -25 °C — 60 °C (brevis terminus (usque ad 24 horas), -60 °C ad 70°C) -25 °C — 60 °C (brevis terminus (usque ad 24 horas), -60 °C ad 70°C)
Ambiens temperatus (congregavit) -5 °F - 70 °C -5 °F - 70 °C -5 °F - 70 °C -5 °F - 70 °C
Ambiens temperatus (exsecutio) -5 °F - 70 °C -5 °F - 70 °C -5 °F - 70 °C -5 °F - 70 °C
Relativum Umor (Repono / Lorem) 30 % — 70% 30 % — 70% 30 % — 70% 30 % — 70%
Environmental amica
RoHS Non ancipitia substantiae supra limina values Non ancipitia substantiae supra limina values Non ancipitia substantiae supra limina values Non ancipitia substantiae supra limina values
Signa et Specificationes
Connectiones sunt vexillum EN61238-1, EN60947-7-2 EN61238-1, EN60947-7-2 EN61238-1, EN60947-7-2 EN61238-1, EN60947-7-2

  • Priora:
  • Next:

  •