• page_head_bg

Products

JUT15-10X2.5(Push-in nexus, distributio obstruit, Terminatio obstruit, distributio boxes)

Description:

Potentiae distributio caudices, clausores terminales inter se utentes spiculis conductoris ponri possunt, correspondentes obturaculum in pontibus inveniri possunt in accessoriis ad fundum.

Moduli verticales vel paralleli clausurae ascendentes.

Nominales operandi intentione: 690 V, Nominalis currentis operandi: 24 A, Methodus Wiring: Dis-in connexione.

Crucis Sectio: 0.14 – 4mm2.

Modus instruitur: NS 35/7,5,NS 35/15,NS15/5.5。


Technical data

Negotium Data

Download

Certification

Product Tags

Commodum

Iuxta parallelam DIN rail institui potest, excepto usque ad 50 spatium e regiones clausurae.

Potest institui per DIN rail, directam institutionem vel institutionem adhaesivam, quae magis flexibilis est ad usum.

Tempus salutaris filum iunctio gratias ad instrumentum libero dis-in nexu technologiae

Colores diversi, wiring clarius est.

Overview

Connection modum In-linea
Numerus ordinum 1
Potentiales 1
Numerus hospitum 7
Apertum latus panel NO
Nulla materia PA
Flamma retardat gradus, in linea cum UL94 V0
Applicationem agri Late usus est in nexu electrica, industria, etc.
Color gray、dark gray、green、 yellow、cream、orange、black、red、blue、white、purple、Brown

Wiring Data

Contactus onus
Tandem nudare 8 mm - 10 mm
Rigid Conductor Cross Section 0.14 mm² — 4 mm²
Flexibile sectione transversali conductor 0.14 mm — 2.5 mm²
Rigid Conductor Cross Section AWG 26 — 12
Flexible Conductor Cross Section AWG 26 — 14

Magnitudo

Crassitudo 29.9mm
Latitudo 28.8mm
Summus 21.7mm

Environmental conditionibus

Ambiens temperatus (operans) -60 °C - 105 °C (max. breve tempus temperatus operating RTI Elec.)
Ambiens temperatus (repono / onerariam) -25 °C — 60 °C (pro brevi, non excedente 24 h, -60 °C ad +70°C)
Ambiens temperatus (congregavit) -5 °F - 70 °C
Ambiens temperatus (exsecutio) -5 °F - 70 °C
Licet humiditas (repono / onerariis) 30 % — 70%

UL parametri Electrical

Latin test E60425
Rated voltage(Usus Group B) 300V
Rated current( usus Group B) 20A
Rated voltage(Usus Group C) 300V
Rated current-Usus Group C) 20A
Rated voltage(Usus Group D) 600V
Rated current( usus Group D) 5A

IEC parametri Electrical

Latin test DE1-62701
Pollutio gradu 3
Overvoltage classis III
Nulla materia coetus I
Rated voltage(III/3) 690V
Ratum current(III/3) 24A
Rated fluctu voltage 9.8kV

Electrical perficientur test

Requisita, voltage gutta 1.89kV
Tentatio gutta test eventus Transierunt test
Temperatus oritur test eventus Transierunt test

Environmental amica

RoHS Non nimium nocivis substantiae

Cautiones

1、 Maximum onus currentis unius figmenti fabrica excedere non debet.
2、 Cum plures terminales continuos inaugurari, commendatur ut DIN rail adaptor infra terminum terminalem instituatur vel inter terminales LABIUM.


  • Previous: