Verticaliter vel parallele ad ferream DIN installari potest, usque ad 50% spatii ferrei conservans.
Installari potest per ferream DIN, institutionem directam, vel institutionem glutinosam, quae flexibilior est ad usum.
Nexus filorum tempus conservans propter technologiam connexionis impulsivae sine instrumentis
Moduli statim sine ponte manuali installari possunt, usque ad 80% temporis conservantes.
Coloribus diversis, filorum conexio clarior est.
descriptio producti | |||||
Imago Producti | |||||
Numerus producti | JUT15-4x2.5-P | JUT15-6x2.5-P | JUT15-10x2.5-P | JUT15-12x2.5-P | JUT15-18x2.5-P |
genus producti | Blocum distributionis filorum ferriviariorum | Blocum distributionis filorum ferriviariorum | Blocum distributionis filorum ferriviariorum | Blocum distributionis filorum ferriviariorum | Blocum distributionis filorum ferriviariorum |
Structura mechanica | Nexus vernalis insertus | Nexus vernalis insertus | Nexus vernalis insertus | Nexus vernalis insertus | Nexus vernalis insertus |
strata | 1 | 1 | 1 | 1 | 1 |
Electricuspotentia | 1 | 1 | 1 | 1 | 1 |
volumen connexionis | 4 | 6 | 10 | 12 | 18 |
Sectio transversalis aestimata | 2.5 mm2 | 2.5 mm2 | 2.5mm2 | 2.5mm2 | 2.5mm2 |
Current aestimatus | 24A | 24A | 24A | 24A | 24A |
Tensio aestimata | 690V | 690V | 690V | 690V | 690V |
tabula lateralis aperta | no | no | no | no | no |
pedes terrestres | no | no | no | no | no |
alius | Ferrivia coniungens sedem ferriviariam PAD-NS15/35 instituere debet. | Ferrivia coniungens sedem ferriviariam PAD-NS15/35 instituere debet. | Ferrivia coniungens sedem ferriviariam PAD-NS15/35 instituere debet. | Ferrivia coniungens sedem ferriviariam PAD-NS15/35 instituere debet. | Ferrivia coniungens sedem ferriviariam PAD-NS15/35 instituere debet. |
Campus applicationis | Late in nexibus electricis, industrialibus adhibitum | Late in nexibus electricis, industrialibus adhibitum | Late in nexibus electricis, industrialibus adhibitum | Late in nexibus electricis, industrialibus adhibitum | Late in nexibus electricis, industrialibus adhibitum |
color | griseus...griseus obscurus...viridis...flavus...cremor...aurantiacus...niger...ruber...caeruleus...albus...purpureus...Fuscus...configurabilis | griseus...griseus obscurus...viridis...flavus...cremor...aurantiacus...niger...ruber...caeruleus...albus...purpureus...Fuscus...configurabilis | griseus, griseus obscurus, viridis, flavus, cremeus, aurantiacus, niger, ruber, caeruleus, albus, purpureus, fuscus, configurabilis | griseus, griseus obscurus, viridis, flavus, cremeus, aurantiacus, niger, ruber, caeruleus, albus, purpureus, fuscus, configurabilis | griseus, griseus obscurus, viridis, flavus, cremeus, aurantiacus, niger, ruber, caeruleus, albus, purpureus, fuscus, configurabilis |
Data filorum | |||||
contactus linearis | |||||
Longitudo nudandi | 8mm —decemmm | 8mm —decemmm | 8mm —decemmm | 8mm —decemmm | 8mm —decemmm |
Sectio Transversa Conductoris Rigidi | 0.14mm²—4mm² | 0.14mm²—4mm² | 0.14mm²—4mm² | 0.14mm²—4mm² | 0.14mm²—4mm² |
Sectio transversalis conductoris flexibilis | 0.14mm²—2.5mm² | 0.14mm²—2.5mm² | 0.14mm²—2.5mm² | 0.14mm²—2.5mm² | 0.14mm²—2.5mm² |
Sectio Transversa Conductoris Rigidi AWG | 26-12 | 26-12 | 26-12 | 26-12 | 26-12 |
Sectio Transversa Conductoris Flexibilis AWG | 26-14 | 26-14 | 26-14 | 26-14 | 26-14 |
Magnitudo (Haec est magnitudo sustentatoris ferriviae portatilis JUT15P PAD-NS15/35 in ferrivia installati) | |||||
crassitudo | 28.8mm | 28.8mm | 28.8mm | 28.8mm | 28.8mm |
latitudo | 58.5mm | 58.5mm | 58.5mm | 58.5mm | 58.5mm |
altus | 21.7mm | 21.7mm | 21.7mm | 21.7mm | 21.7mm |
NS35/7.5 altus | 32.5mm | 32.5mm | 32.5mm | 32.5mm | 32.5mm |
NS35/15 altus | 40mm | 40mm | 40mm | 40mm | 40mm |
NS15/5.5 altus | 30.5mm | 30.5mm | 30.5mm | 30.5mm | 30.5mm |
Proprietates materiales | |||||
Gradus ignifugus, secundum UL94 | V0 | V0 | V0 | V0 | V0 |
Materiae Insulationis | PA | PA | PA | PA | PA |
Grex materiarum insulationis | I | I | I | I | I |
IEC电气参数Parametri electrici IEC | |||||
测试标准examen normatum | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 |
Tensio aestimata()III/3() | 690V | 690V | 690V | 690V | 690V |
Current aestimatus()III/3() | 24A | 24A | 24A | 24A | 24A |
Tensio impulsiva aestimata | 8kv | 8kv | 8kv | 8kv | 8kv |
Classis supertensionis | III | III | III | III | III |
gradus pollutionis | 3 | 3 | 3 | 3 | 3 |
Examen functionis electricae | |||||
Resultata Probationis Tensionis Impulsivae | Examen superavit | Examen superavit | Examen superavit | Examen superavit | Examen superavit |
Resultata probationis tensionis sustinendae frequentiae potentiae | Examen superavit | Examen superavit | Examen superavit | Examen superavit | Examen superavit |
Resultata probationis augmenti temperaturae | Examen superavit | Examen superavit | Examen superavit | Examen superavit | Examen superavit |
condiciones ambientales | |||||
Temperatura ambientis (operans) | -60°C — 105°C (Temperatura maxima operationis brevis temporis, proprietates electricae ad temperaturam pertinentes sunt.) | -60°C — 105°C (Temperatura maxima operationis brevis temporis, proprietates electricae ad temperaturam pertinentes sunt.) | -60°C — 105°C (Temperatura maxima operationis brevis temporis, proprietates electricae ad temperaturam pertinentes sunt.) | -60°C — 105°C (Temperatura maxima operationis brevis temporis, proprietates electricae ad temperaturam pertinentes sunt.) | -60°C — 105°C (Temperatura maxima operationis brevis temporis, proprietates electricae ad temperaturam pertinentes sunt.) |
Temperatura ambientis (repositorium/transportatio) | -25°C — 60°C (brevi tempore (usque ad 24 horas), -60°C ad +70°C) | -25°C — 60°C (brevi tempore (usque ad 24 horas), -60°C ad +70°C) | -25°C — 60°C (brevi tempore (usque ad 24 horas), -60°C ad +70°C) | -25°C — 60°C (brevi tempore (usque ad 24 horas), -60°C ad +70°C) | -25°C — 60°C (brevi tempore (usque ad 24 horas), -60°C ad +70°C) |
Temperatura ambientis (compositum) | -5°C—70°C | -5°C—70°C | -5°C—70°C | -5°C—70°C | -5°C—70°C |
Temperatura ambientis (exsecutio) | -5°C—70°C | -5°C—70°C | -5°C—70°C | -5°C—70°C | -5°C—70°C |
Humiditas Relativa (Conservatio/Transportatio) | Triginta centesimae—70% | Triginta centesimae—70% | Triginta centesimae—70% | Triginta centesimae—70% | Triginta centesimae—70% |
Amicabilis ambienti | |||||
RoHS | Nullae substantiae nimis noxiae | Nullae substantiae nimis noxiae | Nullae substantiae nimis noxiae | Nullae substantiae nimis noxiae | Nullae substantiae nimis noxiae |
Normae et Specificationes | |||||
Nexus sunt normales | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 |