Description:

Cochleae genus scandali terminalis industrialis fortis stabilitatem connexionis stabilitatis habet, mobilitatem altam, et cito in cancellos ductoris U informibus et G informibus cancellos ductoris constitui potest.Accessiones copiosae et practicae.Institutio et certa.

Operatio current: 17.5 A,operans intentione500V

Wiring modus: cochleae connexio.

Ratum wiring facultatem: 1.5 mm2

Modus instruitur: NS 35/7.5,NS 35/15, NS32.


Technical data

Negotium Data

Download

Certification

Product Tags

Commodum

Universalis pes ascendens, praesto pro cancellis NS35 et NS32.

Static connexio stabilitas fortis est.

Potentia distributio pontium.

Descriptio

Product numerus JUT1-1.5 JUT1-1.5PE
genus productum Rail Terminals Rail terram terminalem
Mechanica structura genus stupra genus stupra
stratis 1 1
Electric potential 1 1
nexum volumen 2 2
Rated sectione transversali 1.5 mm2 1.5 mm2
Ratum current 17.5A 17.5A
Rated voltage 500V 500V
apertum latus panel Ita no
grounding pedes no Ita
alius    
Applicationem agri Late in nexu electrica, industriae Late in nexu electrica, industriae
color gray、dark gray、green、 yellow、cream、orange、black、red、blue、white、purple、Brown、customizable flavo viridis

Wiring Data

linea contactus
Tandem nudare 7mm 7mm
Rigid Conductor Cross Section 0.14mm² — 1.5mm² 0.14mm² — 1.5mm²
Flexibile sectione transversali conductor 0.14mm² — 1.5mm² 0.14mm² — 1.5mm²
Rigid Conductor Cross Section AWG 26 — 16 26 — 16
Flexible Conductor Cross Section AWG 26 — 16 26 — 16

Magnitudo

Crassitudo 4.2mm 4.2mm
Latitudo 42.5mm 42.5mm
Summus
NS35/7.5 altum 42mm 47mm
NS35/15 altum 49.5mm 54.5mm
NS15/5.5 altum

Materia Properties

Flamma retardat gradus, in linea cum UL94 V0 V0
Nulla materia PA PA
Nulla materia coetus I I

IEC Electrical Parameters

Latin test IEC 60947-7-1 IEC60947-7-2
Rated voltage(III/3) 500V 500V
Ratum current(III/3) 17.5A 17.5A
Rated fluctu voltage 6kv 6kv
Overvoltage classis III III
Pollutio gradu 3 3

Electrica euismod Test

Surge Voltage Test Results Transierunt test Transierunt test
Potestas frequentiae sustinere voltage test eventus Transierunt test Transierunt test
Temperatus oritur test eventus Transierunt test Transierunt test

Environmental Conditions

Ambiens temperatus (operando) -60 °C — 105 °C (Maximum breve tempus temperaturae operating, notae electricae relatae sunt ad temperiem). -60 °C — 105 °C (Maximum breve tempus temperaturae operating, notae electricae relatae sunt ad temperiem).
Ambiens temperatus (repono / onerariam) -25 °C — 60 °C (brevis terminus (usque ad 24 horas), -60 °C ad 70°C) -25 °C — 60 °C (brevis terminus (usque ad 24 horas), -60 °C ad 70°C)
Ambiens temperatus (congregavit) -5 °F - 70 °C -5 °F - 70 °C
Ambiens temperatus (exsecutio) -5 °F - 70 °C -5 °F - 70 °C
Relativum Umor (Repono / Lorem) 30 % — 70% 30 % — 70%

Environmental Friendly

RoHS Non nimium nocivis substantiae Non nimium nocivis substantiae

Signa et Specificationes

Connectiones sunt vexillum IEC 60947-7-1 IEC 60947-7-2